--------------------------------------------------------------------------- Golden DOM location S39- 10,11,16,56,57 --------------------------------------------------------------------------- Flasherboard Mask |------ bottom -------| |-------- top --------| D12 D11 D10 D09 D08 D07 D06 D05 D04 D03 D02 D01 |-------------| |-------------| |-------------| FC0: flash the bottom LEDs (horizontal) 3F: flash the top LEDs FFF: flash all LEDs --------------------------------------------------------------------------- Meaning of the Run Tags (Brendan Fox) (1) INTRA-1LED - Intra-String Single LED "In-Water" Study In each run, one of the 12 flasherboard LEDs is pulsed. A run is collected for each of these LEDs. The LED settings are intensity=48, and pulse width=10 ns. Typically only DOMs on the flashing string are readout, though others may be readout depending on availability of other strings. The aim of these data is to study possible phi-dependence via light seen by the same string that is being flashed. (2) W2F-1LED - "Wet To Frozen" Single LED "In-Water" Study In each run, one of the 12 flasherboard LEDs is pulsed. A run is collected for each of these LEDs. The LED settings are intensity=127 and pulse width=50 ns. The readout will include a frozen string (i.e. string 21) and the flashed string, though additional strings may be readout if available. The aim of these data is to study possible phi-dependence via light seen by a "stable" (i.e. frozen) string near the one being flashed. (3) INTRA-TDEP - Intra-String Time-Dependence "In-Water" Study In each run, either all the vertical or all the horizontal flasherboard LEDs are pulsed. A run is collected for each of these sets. The LED settings are intensity=48 and pulse width=10 ns. Typically, only DOMs on the flashing string are readout, though others may be readout depending on availability of other strings. The aim of these data is to study the time-dependence of the freezing process via light seen by the same string that is being flashed. (4) W2F-TDEP - "Wet to Frozen" Time-Dependence "In-Water" Study In each run, either all the vertical or all the horizontal flasherboard LEDs are pulsed on the string which is recently deployed. A run is collected for each of these sets. The LED settings are intensity=127 and pulse width=50 ns. The readout will include string 21 and the flashed string, though additional strings may be readout if they are available. The aim of these data is to study the time-dependence of the freezing process via light seen on a "stable" (i.e. frozen) string near the one being flashed. (5) F2W-TDEP - "Frozen to Wet" Time-Dependence "In-Water" Study In each run, either all the vertical or all the horizontal flasherboard LEDs are pulsed on a stable (i.e. frozen) string near a recently deployed string. A run is collected for each of these sets. The LED settings are intensity=127 and pulse width=50 ns. The readout will include the frozen string (i.e. string 21) and the recently deployed string under investigation, though additional strings may be readout if they are available. The aim of these data is to study the time-dependence of the freezing process via light from a "stable" (i.e. frozen) string seen on the recently deployed string (which should be near the frozen string). (6) INITVER - Initial Timing & Geometry Verification with Flasher In each run, all 12 flasherboard LEDs are pulsed for a single DOM on a string which is being verified. The LED settings are intensity=127 and pulse width=10 ns. The readout will include the string being flashed, though additional strings may be readout if they are available. The aim of these data is to study the timing and geometry of the string. Typically, these data will be collected when the Top-36 or Top-48 DOMs have frozen. (7) FBOUT-VER - Flasherboard Output Verification Study Typically, these data are collected on two strings, concurrently, by flashing a DOM at the top of one string and the bottom of the other In each run, one of the 12 flasherboard LEDs on the selected DOMs is pulsed. A run is collected for each of these LEDs. The LED settings are intensity=127 and pulse width=50 ns. The readout must include the flashed strings, though additional strings may be readout if they are available. The aim of these data is to study the brightness of the LEDs as seen in the Ice and compare this brightness with measurements during FAT. (8) PMTLIN-VER - PMT Linearity Verification Study To measure the PMT linearity, we use runs in which the LEDs are flashed progressively brighter, either by increasing the intensity or by flashing additional flashes. All told, each measurement involves X runs. Each run has 16 DOMs flashing on each of two strings. The aim of these data is to study the PMT linearity for and also the afterpulsing properties when the DOMs are in ice. The results will be compared with FAT data. --------------------------------------------------------------------------- ATWD channel 3 (David Atlee) a) In general: What is ATWD-3 (i.e. the 4th) used for? First, the general convention that we use is to refer to ATWD channel 3 rather than ATWD 3, because each DOM actually has 2 ATWDs on board, and those are called ATWD 0 and 1. I'm sure you can see how this might get confusing. That being said, channel 3 is a utility channel that carries different content during different types of runs. For "normal" data taking runs, it usually contains a digitization of the DOM's on-board clock. However, this is not necessarily true. In general, one does not need to worry about channel 3 unless one is doing very specific analysis a2) What is it doing during flasher runs in the flashing DOM? During flasher runs, channel 3 receives and digitizes a copy of the voltage signal being sent to the LEDs this allows us to determine at what time the flashers on the DOM turned on by looking at the leading edge time of the rise in driving voltage. a3) What are the other ATWDs doing during flashing? I'm pretty sure this is configurable, but during flasher runs, the HV to the flashing DOM is switched off to avoid damage to the PMT, so the ATWD channels (as well as the Flash ADC) that would normally digitize a PMT signal are switched off as well. b) When do the ATWDs use 64bins and when 128bins? Why? The DOMs have a configurable parameter that tells the DOM how many ATWD samples it should use. There are also options that allow 16 and 32 sample waveforms. The choice of sample size is generally based on the data volume expected over the wire pair, and is generally chosen to provide the best balance between waveform completeness and high data rates. The length of the waveform is often different for different types of runs.