GRB230111A

This page lists all entries on GRB230111A in GRBweb

Summary Fermi GBM IPN GCN 33156 GCN 33157 GCN 33162

Summary table
Variable Value Source
GRB_name_Fermi GRB230111797
T0 19:07:37 UTC GCN_circulars,MAXI Det
ra 320.1875° IPN
decl -30.4833° IPN
pos_error 1.00e+00° IPN
T90 8.704 s Fermi_GBM
T90_error 1.493 s Fermi_GBM
T90_start 19:07:38.547 UTC Fermi_GBM
fluence 1.00e-06 erg/cm² Fermi_GBM
fluence_error 2.13e-08 erg/cm² Fermi_GBM
T100 10.251 s
GBM_located False
mjd 59955.796956018516 GCN_circulars,MAXI Det
Fermi GBM table
GRB_name_Fermi GRB230111797
trigger_name bn230111797
ra 320.1879°
decl -30.5769°
pos_error 6.98e+00°
datum 2023-01-11
t_trigger 19:07:42.899 UTC
T90 8.704 s
T90_error 1.493 s
T90_start 19:07:38.547 UTC
fluence 1.00e-06 erg/cm²
fluence_error 2.13e-08 erg/cm²
flux_1024 2.56e+00 erg/cm²/s
flux_1024_error 2.70e-01 erg/cm²/s
flux_1024_time -8.96e-01 erg/cm²/s
flux_64 5.22e+00 erg/cm²/s
flux_64_error 1.43e+00 erg/cm²/s
IPN table
GRB_name GRB230111A
ra 320.1875°
decl -30.4833°
pos_error 1.00e+00°
GCN 33156 table
GRB_name GRB230111A
GCN_number 33156
Detection_method Fermi GBM final loc
t_trigger 19:07:42 UTC
ra 316.1000°
decl -22.5000°
Circular_text TITLE: GCN CIRCULAR NUMBER: 33156 SUBJECT: GRB 230111A: Fermi GBM Final Real-time Localization DATE: 23/01/11 19:18:06 GMT FROM: Fermi GBM Team at MSFC/Fermi-GBM The Fermi GBM team reports the detection of a likely LONG GRB At 19:07:42 UT on 11 Jan 2023, the Fermi Gamma-ray Burst Monitor (GBM) triggered and located GRB 230111A (trigger 695156867.898656 / 230111797). The on-ground calculated location, using the Fermi GBM trigger data, is RA = 316.1, Dec = -22.5 (J2000 degrees, equivalent to J2000 21h 04m, -22d 30'), with a statistical uncertainty of 8.9 degrees. The angle from the Fermi LAT boresight is 100.0 degrees. The skymap can be found here: https://heasarc.gsfc.nasa.gov/FTP/fermi/data/gbm/triggers/2023/bn230111797/quicklook/glg_skymap_all_bn230111797.png The HEALPix FITS file, including the estimated localization systematic, can be found here: https://heasarc.gsfc.nasa.gov/FTP/fermi/data/gbm/triggers/2023/bn230111797/quicklook/glg_healpix_all_bn230111797.fit The GBM light curve can be found here: https://heasarc.gsfc.nasa.gov/FTP/fermi/data/gbm/triggers/2023/bn230111797/quicklook/glg_lc_medres34_bn230111797.gif
GCN 33157 table
GRB_name GRB230111A
GCN_number 33157
Detection_method MAXI Det
t_trigger 19:07:37 UTC
ra 320.1880°
decl -30.5770°
Circular_text TITLE: GCN CIRCULAR NUMBER: 33157 SUBJECT: GRB 230111A: MAXI/GSC detection DATE: 23/01/12 00:28:35 GMT FROM: Motoko Serino at Aoyama Gakuin U. K. Setoguchi(Kyoto U.), T. Mihara (RIKEN), M. Serino (AGU), H. Negoro, M. Nakajima, K. Kobayashi, M. Tanaka, Y. Soejima (Nihon U.), T. Kawamuro, S. Yamada, T. Tamagawa, M. Matsuoka (RIKEN), T. Sakamoto, S. Sugita, H. Hiramatsu, H. Nishikawa, A. Yoshida (AGU), Y. Tsuboi, J. Kohara, S. Urabe, S. Nawa, N. Nemoto (Chuo U.), M. Shidatsu, M. Iwasaki (Ehime U.), N. Kawai, M. Niwano, R. Hosokawa, Y. Imai, N. Ito, Y. Takamatsu (Tokyo Tech), S. Nakahira, S. Ueno, H. Tomida, M. Ishikawa, T. Kurihara (JAXA), Y. Ueda, S. Ogawa, T. Yoshitake, K. Inaba, Y. Nakatani (Kyoto U.), M. Yamauchi, T. Sato, R. Hatsuda, R. Fukuoka, Y. Hagiwara, Y. Umeki (Miyazaki U.), K. Yamaoka (Nagoya U.), Y. Kawakubo (LSU), M. Sugizaki (NAOC) , W. Iwakiri (Chiba U.) report on behalf of the MAXI team: The MAXI/GSC nova alert system triggered a bright uncatalogued X-ray transient source at 19:07:37 UT on 11 Jan 2023. Assuming that the source flux was constant over the transit, we obtain the source position at (R.A., Dec) = (320.188 deg, -30.577 deg) = (21 20 45, -30 34 36) (J2000) with a 90% C.L. statistical error of 0.22 deg and an additional systematic uncertainty of 0.1 deg (90% containment radius). Without assumptions on the source constancy, we obtain a rectangular error box for the transient source with the following corners. (319.214, -30.721) deg = (21 16 51, -30 43 15) (J2000) (319.406, -31.127) deg = (21 17 37, -31 07 37) (J2000) (321.653, -30.323) deg = (21 26 36, -30 19 22) (J2000) (321.454, -29.920) deg = (21 25 48, -29 55 12) (J2000) The X-ray flux averaged over the scan was 230 +- 30 mCrab (4.0-10.0keV, 1 sigma error). There was no significant excess flux in the previous transit at 17:34 UT and in the next transit at 20:40 UT with an upper limit of 20 mCrab for each.
GCN 33162 table
GRB_name GRB230111A
GCN_number 33162
Detection_method Fermi GBM Det
t_trigger 19:07:42.900 UTC
Circular_text TITLE: GCN CIRCULAR NUMBER: 33162 SUBJECT: GRB 230111A: Fermi GBM Observation DATE: 23/01/12 17:54:28 GMT FROM: Oliver J Roberts at USRA/NASA O.J. Roberts (USRA) and C. Meegan (UAH) report on behalf of the Fermi Gamma-ray Burst Monitor Team: "At 19:07:42.90 UT on 11 January 2023, the Fermi Gamma-ray Burst Monitor (GBM) triggered and located GRB 230111A (trigger 695156867/230111797), which was also detected by MAXI (K. Setoguchi et al. 2023, GCN 33157). The Fermi GBM Localization reported in GCN 33156 is consistent with the MAXI location. The angle from the Fermi LAT boresight is 108 degrees. The GBM light curve consists of a single peak with a duration (T90) of about 9 s (50-300 keV). The time-averaged spectrum from T0-3.6 to T0+4.8 s is best fit by a power law function with an exponential high-energy cutoff. The power law index is -0.31 +/- 0.30 and the cutoff energy, parameterized as Epeak, is 122 +/- 16 keV. The event fluence (10-1000 keV) in this time interval is (1.16 +/- 0.12)E-06 erg/cm^2. The measured 1-s peak photon flux starting from T0-0.9 s in the 10-1000 keV band is 2.6 +/- 0.3 ph/s/cm^2. The spectral analysis results presented above are preliminary; final results will be published in the GBM GRB Catalog: https://heasarc.gsfc.nasa.gov/W3Browse/fermi/fermigbrst.html For Fermi GBM data and info, please visit the official Fermi GBM Support Page: https://fermi.gsfc.nasa.gov/ssc/data/access/gbm/"