SETUP | |
short cable | ~10 meter DOR <--> DOM cable |
medium cable | ~500 meter DOR <--> DOM cable |
twisted cable | 20 meter DOR <--> DOM twisted pair cable |
DOR firmware | DC_005h.rbf 568 |
DOR driver | 1.134 |
DOM | rev 3 |
V power supply | 91.5 Volts |
V across the filters | range is 5.7 to 6.2 Volts |
current through DOM | ~39mA |
Do any other wire pairs have a load? | NO |
Is there any difference if wire pair 1 is used and wire pair 0 is left open? | NO |
SETUP | CABLE | FILTER | POWER-UP | RESULT | ADVICE (received Jan 20-21) |
| |||||
| short cable | | | everything works, see rapcal plot this is the typical pirate domhub configuration of the last three months | |
| short cable | | | ||
| medium cable | | | communications work until the exact moment
of the termination of the "on 0 0" command, see rapcal plot
this means there are approximately 15 seconds of succesful communications, and the "on" command incorrectly claims success as it terminates once comms wouldn't work at all, changed cables, verified DOM<-->DOR comms, changed cables back, and comms worked again (here, "worked" equals the "15 seconds" DOM!) |
Kalle says that he has tested communications with the following cable lengths: 0, 17, 150, 1500, 3500 m, and that perhaps 500 meters is a problem |
| medium cable | | | communications never work compare to setup 3 !!! DOM sends out reboot message, "on" command incorrectly claims success as it terminates | |
| short cable | | | everything works, see rapcal plot | |
| short cable | | | ||
| medium cable | | | communications never work | |
| medium cable | | | ||
| short cable | | | everything works, see rapcal plot | |
| short cable | | | communications never work compare to setup 9 !!! | |
| medium cable | | | everything works, see rapcal
plot compare to setups 3 and 4 !! |
|
| medium cable | | | ||
| short cable | | | everything works once comms wouldn't work, don't know why | |
| short cable | | | ||
| medium cable | | | communications never work | |
| medium cable | | |