2010-11 South Pole DOMHub Testing at SPTS64

last updated 9/13 16:00 CDT by krasberg

Instructions

SPTS64 Hub Testing Schedule/Results

ALL tests on spts64-scube because no DOMHubs could be kickstarted

HUB

Start of Tests

Results

Retest Desired?

Current Status

scube Aug 27 6: SCUBE-28 27738cd0ed22 localhost.31A dropped from data stream multiple times no 8 old scube DOR cards passed
scube Sep 3   no 8 new DOR cards passed
scube Sep 10/11 two DOR cards failed R1B1000D06 crashes DOMHub when DOMs go to iceboot, another card blew fuses but this was traced to a short in the quad cable no, except for the DOR card which blew fuses because of the short int he quad cable 6 new DOR cards passed
scube Sep 13 retesting card from prior test, and 7 new ones no 8 new DOR cards passed
scube Sep 14 Swapped DOR cards between one of the new domhubs and scube. Now 8 new DOR cards are being tested. card R1B1352D07 WP0 shows high config and iceboot currents (91mA), firmwarefuses blown on that wire pair during MOAT test. cable test show short on Wp0. Fixed conenctor and checked harware fuses: they are all ok! Restarted testing, now currents look fine. We deleted the entries for those cards in the offset file and rerun the offset script no 8 DOR cards passed and moved to one of the new domhubs
scube Sep 15 Put two 'new' DOR cards in scube on 0 and 1, the other cards are all from the old scube. Will run testdaq on the whole system in order to test the two new dor cards that were discovered: one was labelled 'to be retested' (R1B0469D04) and the other one was labelled 'previously used' (R1B0612D05) no 2 DOR cards passed and labelled and put aside
scube Sep 16 Removed he two tested DOR cards from scube and put the two old ones back into place.    

Other events of note

Brief instructions